Elmo Server 1.3 Manuale Utente

Navigare online o scaricare Manuale Utente per no Elmo Server 1.3. Elmo Server 1.3 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 74
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Tuba
Digital Servo Drive
Installation Guide
April 2008 (Ver. 1.3)
www.elmomc.com
Vedere la pagina 0
1 2 3 4 5 6 ... 73 74

Sommario

Pagina 1 - Installation Guide

Tuba Digital Servo Drive Installation Guide April 2008 (Ver. 1.3) www.elmomc.com

Pagina 2 - TUB- AX/YYY

Tuba Installation Guide Introduction MAN-TUBIG (Ver. 1.3) 2-2 2.2.3 Position Control  Programmable PIP control filter  Programmable notch and low-

Pagina 3 - Contents

Tuba Installation Guide Introduction MAN-TUBIG (Ver. 1.3) 2-3  Elmo drives provide supply voltage for all the feedback options 2.2.7 Fault Protec

Pagina 4

Tuba Installation Guide Introduction MAN-TUBIG (Ver. 1.3) 2-4 2.4 How to Use this Guide In order to install and operate your Elmo Tuba servo drive,

Pagina 5

Chapter 3: Installation 3.1 Before You Begin 3.1.1 Site Requirements You can guarantee the safe operation of the Tuba by ensuring that it is installe

Pagina 6 - Tuba Installation Guide

3.1.2.3 Power Connectors Component Connector Described in Section Photo External DC Link Cable B1, B2 on External DC Link Cable 3.4.2.3 Main Power

Pagina 7 - 1.2 Cautions

3.1.2.5 Feedback and I/O Connectors Component Port on Tuba Described in Section Diagram Analog Inputs (if needed) ANALOG I/O 3.4.8.1 CEL0040A-DWGC

Pagina 8 - 1.5 Warranty Information

3.1.2.6 Other Items Needed Component Described in Section Diagram PC for drive setup and tuning Motor data sheet or manual 3.2 Unpacking the D

Pagina 9 - 2.2.2 Velocity Control

3.3 Mounting the Tuba The Tuba has been designed for two standard mounting options:  Attaching directly to the wall with screws  Mounting on a DI

Pagina 10 - 2.2.6 Feedback Options

3.3.2 Mounting on a DIN Rail At the top rear of the Tuba, a horizontal groove lets you quickly and easily snap the drive onto a DIN rail in your work

Pagina 11 - 2.3 System Architecture

Press the Tuba down to a vertical position until it clicks onto the DIN rail. Figure 3-4: Tuba Mounted on DIN Rail 3.4 Connecting the Cables 3.4.1

Pagina 12 - 2.4 How to Use this Guide

Notice This guide is delivered subject to the following conditions and restrictions:  This guide contains proprietary information belonging to Elmo

Pagina 13 - Chapter 3: Installation

 Keep the motor wires as far away as possible from the feedback, control and communication cables.  Ensure that in normal operating conditions, th

Pagina 14 - 3.1.2.3 Power Connectors

Figure 3-5: Tuba Detailed Connection Diagram Tuba Installation Guide Installation MAN-TUBIG (Ver. 1.3) 3-9

Pagina 15 - 3.4.8.3

3.4.2 Connecting the Power Cables Access the power terminal connections on the Tuba servo drive by removing the front safety cover located at the bot

Pagina 16 - 3.1.2.6 Other Items Needed

3.4.2.1 Connecting the Motor Cable Connect the motor power cable to the M1, M2, M3 and PE terminals of the main power connector. The phase connection

Pagina 17 - 3.3 Mounting the Tuba

3.4.2.2 Connecting the Main Power Cable Connect the main power supply cable to the AC1, AC2 and AC3 terminals of the main power connector. Connect th

Pagina 18 - MAN-TUBIG (Ver. 1.3)

3.4.3 Connecting the Auxiliary Supply Cable (24v) Connect the auxiliary supply to the 24VDC terminal block on the bottom of the Tuba. Remember, you a

Pagina 19 - 3.4.1 Wiring the Tuba

3.4.4 Feedback and Control Cable Assemblies The Tuba features easy-to-use D-sub type connections for all Control and Feedback cables. Below are instr

Pagina 20

3.4.5 Main Feedback Cable (Feedback A) The main feedback cable is used to transfer feedback data from the motor to the drive. The Tuba accepts the f

Pagina 21

Absolute Encoders TUB XX/YYYQ Pin Signal Heidenhain Stegmann 1 HC Hall C Hall C 2 HA Hall A Hall A 3 SUPRET Supply return Supply return

Pagina 22 - 3-7: Tuba Power Connectors

10151487Incremental Encoderwith Hall SensorTubaFeedback A1Hall CHall BCHBCHB-INDEXINDEX-CHACHA-2512Encoder / Hall +5v SupplyHall / Encoder Supply /

Pagina 23

Contents Chapter 1: Safety Information...1-1 1.1 Warnings

Pagina 24 - TUB00020B

58743Sine / CosineEncoderFeedback A6TUB0005A1514Encoder +5v SupplyEncoder Supply ReturnB+B-R+R-A+A-+5vSUPRETTubaB+B-R+R-A+A- Figure 3-14: Main Feedba

Pagina 25 - TUB0017A

only one tachometer port is available at a time Figure 3-16: Main Feedback – Tachometer Feedback with Digital Hall Sensor Connection Diagram for Bru

Pagina 26

Figure 3-18: Main Feedback – Potentiometer Feedback with Digital Hall Sensor Connection Diagram for Brushless Motors Figure 3-19: Main Feedback –

Pagina 27 - 3.4.4 (Feedback

Figure 3-20: Main Feedback – Stegmann Feedback Connection Diagram Tuba Installation Guide Installation MAN-TUBIG (Ver. 1.3) 3-21

Pagina 28 - TUB XX/YYYQ

Figure 3-21: Main Feedback – Heidenhain Feedback Connection Diagram Tuba Installation Guide Installation MAN-TUBIG (Ver. 1.3) 3-22

Pagina 29 - TUB0004A

3.4.6 Main and Auxiliary Feedback Combinations The Main Feedback is always used in motion control devices whereas Auxiliary Feedback is often, but n

Pagina 30

FEEDBACK B Ports B1 and B2 FEED- BACK A YA[4] = 4 YA[4] = 2 YA[4] = 0 Potentiometer Input B1 - outputB2 - outputsame as B1A - inputPotentiometerP

Pagina 31

3.4.7 Auxiliary Feedback (FEEDBACK B) When using one of the auxiliary feedback options, the relevant functionality of FEEDBACK B ports are software s

Pagina 32

TubaTubaTubaTuba Figure 3-22: Main Encoder Buffered Output or Emulated Encoder Output on FEEDBACK B - Connection Diagram Tuba Installation Guide

Pagina 33

3.4.7.2 Differential Auxiliary Encoder Input Option on FEEDBACK B (YA[4]=2) The Tuba can be used as a slave by receiving the position of the master e

Pagina 34

3.4.7.4 Pulse-and-Direction Input Option on FEEDBACK B (YA[4]=0)...3-31 3.4.8 I/O Cables...

Pagina 35 - FEEDBACK B Ports B1 and B2

TubaTubaTubaTuba Figure 3-23: Differential Auxiliary Encoder Input Option on FEEDBACK B - Connection Diagram Tuba Installation Guide Installation

Pagina 36

3.4.7.3 Single-ended Auxiliary Input Option on FEEDBACK B (YA[4]=2) The Tuba can be used as a slave by receiving the position data of the master enco

Pagina 37 - Port B1 Power

TubaTubaTubaTuba Figure 3-24: Single-ended Auxiliary Input Option on FEEDBACK B - Connection Diagram Tuba Installation Guide Installation MAN-TUBIG

Pagina 38

3.4.7.4 Pulse-and-Direction Input Option on FEEDBACK B (YA[4]=0) This mode is used for input of differential or single-ended pulse-and-direction posi

Pagina 39 - FEEDBACK B (YA[4]=2)

TubaTubaTubaTuba Figure 3-25: Single-Ended Pulse-and-Direction Input Option on FEEDBACK B - Connection Diagram Figure 3-26: Differential Pulse-and-

Pagina 40

3.4.8 I/O Cables The Tuba has three I/O ports (ANALOG INPUTS, DIGITAL INPUTS AND DIGITAL OUTPUTS) which can be used to connect 2 analog inputs, 10 sep

Pagina 41 - (YA[4]=2)

3.4.8.2 Digital Inputs (on GENERAL I/O Port) The Tuba servo drive is equipped with a 25-pin D-sub plug for digital inputs. When assembling an I/O cab

Pagina 42

Figure 3-28: Digital Inputs (on General I/O port) Connection Diagram Tuba Installation Guide Installation MAN-TUBIG (Ver. 1.3) 3-35

Pagina 43 - (YA[4]=0)

3.4.8.3 Digital Outputs (on COMMITTED I/O Port) The Tuba servo drive is equipped with a 15-pin, high-density, D-sub socket for digital outputs. When

Pagina 44

Tuba Digital Outputs Figure 3-29: Digital Outputs (on COMMITTED I/O port) Connection Diagram Tuba Installation Guide Installation MAN-TUBIG (Ver. 1

Pagina 45 - 3.4.8.1 Analog Inputs

A.14.7 Packing...A-18 A.14.8 Environm

Pagina 46

3.4.9 Communication Cables The communication cables use an 8-pin RJ-45 plug that connect to the RS-232 and CANopen ports on the front of the Tuba. T

Pagina 47

Figure 3-30: RS-232 Connection Diagram 3.4.9.2 CANopen Communication (on the COMM.2 Ports) Notes for connecting the CANopen communication cable:

Pagina 48

7123CAN_GND120ΩCAN - Controller6CAN_HCAN_LDrainWire712367123CAN - InterfaceCAN_GND6CAN_HCAN_L71236CAN_HCAN_LCAN_GNDDrainWireDrainWire7123671236CAN_G

Pagina 49 - Tuba Digital Outputs

3.5 Powering Up After the Tuba has been mounted, check that the cables are intact. The Tuba servo drive is then ready to be powered up. Caution:

Pagina 50 - 3.4.9 Communication Cables

Appendix: Technical Specifications A.1 Features A.1.1 Motion Control Modes • Current/Torque - up to 14 kHz sampling rate • Velocity - up to 7 kHz

Pagina 51

A.1.6 Input/Output • Analog Inputs – up to 14-bit resolution • Programmable digital inputs, optically isolated  Inhibit \ Enable motion  Softwar

Pagina 52 - Caution:

A.2 Tuba Dimensions Rear View Front ViewSide View Tuba Installation Guide Technical Specifications MAN-TUBIG (Ver. 1.3) A-3

Pagina 53 - 3.6 Initializing the System

A.3 Mounting Dimensions Rear View A.4 Mechanical Specifications Feature Details Mounting Method  Wall Mount ("Bookshelf")  DIN Rail Overal

Pagina 54 - A.1 Features

A.5 Power Ratings Feature Units 12/230 15/230 20/230 12/460 15/460 20/460 Minimum supply voltage VAC 60 140 Nominal supply voltage VAC 1 x 115,

Pagina 55 - A.1.7 Built-In Protection

A.7 Tuba Connections The following connectors are used for wiring the Tuba. Pins Type Maker & Part No. Port 5 Motor M1, M2, M3 2 Ground PE,

Pagina 56 - A.2 Tuba Dimensions

Chapter 1: Safety Information In order to achieve the optimum, safe operation of the Tuba servo drive, it is imperative that you implement the safety

Pagina 57 - A.3 Mounting Dimensions

A.7.1 Auxiliary Supply Feature Details Auxiliary power supply DC source only Auxiliary supply input voltage 24 V +15% Auxiliary supply input po

Pagina 58 - A.6 Environmental Conditions

A.8.2 Velocity Loop Feature Details Controller type PI Velocity control  Fully digital  Programmable PI and FFW control filters  On-the-fly gain s

Pagina 59 - A.7 Tuba Connections

A.9 Feedbacks A.9.1 Feedback Supply Voltage Feature Details Main encoder supply voltage 5 V +5% @ 200 mA maximum Auxiliary encoder supply voltage 5

Pagina 60 - A.8.1 Current Loop

A.9.3 Digital Halls Feature Details Halls inputs  HA, HB, HC.  Single ended inputs  Built in hysteresis for noise immunity. Input voltage Nomina

Pagina 61 - A.8.3 Position Loop

A.9.5 Resolver Feature Details Resolver format  Sine/Cosine  Differential Input resistance Differential 2.49 kΩ Resolution Programmable: 10 ~ 15

Pagina 62 - A.9 Feedbacks

A.9.7 Potentiometer Feature Details Potentiometer Format Single-ended Operating Voltage Range 0 ~ 5 V supplied by the Tuba Potentiometer Resistance

Pagina 63 - A.9.3 Digital Halls

A.10 I/Os The Tuba has: 10 Digital Inputs 6 Digital Outputs 2 Analog Inputs A.10.1 Digital Input Interfaces (on GENERAL I/O port) Feature Details

Pagina 64 - A.9.6 Tachometer*

A.10.2 Digital Output Interface (on COMMITTED I/O port) Feature Details Connector Location Type of output  Optically isolated  Open collector and

Pagina 65 - A.9.8 Encoder Outputs

A.10.3 Analog Input Feature Details Maximum operating differential voltage ± 10 V Maximum absolute differential input voltage ± 16 V Differential i

Pagina 66 - A.10 I/Os

A.12 Pulse Width Modulation (PWM) Feature Details PWM resolution 12-bit PWM switching frequency on the load 2/Ts (factory default 22 kHz on the mot

Pagina 67 - DIGITAL OUTPUTS

1.1 Warnings To avoid electric arcing and hazards to personnel and electrical contacts, never connect/disconnect the servo drive while the power sou

Pagina 68 - A.10.3 Analog Input

A.14 Standards Compliance A.14.1 Quality Assurance Specification Details ISO 9001:2000 Quality Management A.14.2 Design Specification Details MIL-H

Pagina 69 - A.13 Single-phase Operation

A.14.6 PCB Specification Details In compliance with IPC-A-600, level 2 Acceptability of printed circuit boards A.14.7 Packing Specification Details

Pagina 70 - A.14 Standards Compliance

Index 2 24v Auxiliary Power Connector · 3-8 A AC Motor Power Connection Diagram · 3-11 Advanced position control · 2-2 Advanced Positioning Motion Con

Pagina 71 - A.14.8 Environmental

Digital Outputs · 3-8 Digital Outputs · 3-36 Dimensions · A-3 DIN rail mounting · 3-6 Documentation Hierarchy · 2-4 E Environmental conditions · A-5 E

Pagina 72

COMMITTED I/O · 3-8 FEEDBACK A · 3-8 FEEDBACK B · 3-8 GENERAL I/O · 3-8 Position control · 2-2 Potentiometer · 3-15, 3-20 Power cables · 3-10 Power Ra

Pagina 73

1.3 Directives and Standards The Tuba conforms to the following industry safety standards: Safety Standard Item Recognized UL508c Power Conversio

Pagina 74

Tuba Installation Guide MAN-TUBIG (Ver. 1.3) 2-1 Chapter 2: Introduction This installation guide describes the Tuba servo drive and the steps for i

Commenti su questo manuale